Bookeye® 4 V2 Professional Archive Book Scanner - Technical Data
This section provides you with the technical specifications and data associated with the Bookeye® 4 V2 Professional Archive book scanner. Speed, scan size, power consumption and environmental data can be found as well as shipping dimensions and weight. These documents are the most detailed summary of the technical specifications.
Bookeye® 4 V2 Professional Archive Book Scanner - Technical Data
Document | |
---|---|
Maximum Document Size | 460 x 620 mm (18 x 24.4 inches), 14% > DIN A2 |
Output | |
Scanner Resolution | 600 x 600 dpi |
Pixel Dimension | 9.3 x 9.3 µm |
Scan Speed Color | DIN A2+ @ 150 dpi: 0.9 s DIN A2+ @ 200 dpi: 1.1 s DIN A2+ @ 300 dpi: 1.6 s DIN A2+ @ 400 dpi: 2.0 s DIN A2+ @ 600 dpi: 3.0 s |
Color Depth | 48 bit color, 16 bit grayscale |
Scan Output | 24 bit color, 8 bit grayscale, bitonal, enhanced halftone |
File Formats | Multipage PDF (PDF/A) and TIFF, JPEG, JPEG 2000, PNM, PNG, BMP, TIFF (Raw, G3, G4, LZW, JPEG), AutoCAD DWF, JBIG, DjVu, DICOM, PCX, Postscript, EPS, Raw data |
ICC Profiles | Embedded for sRGB, Adobe RGB and native. Individual profiling via web based Scan2ICC subscription |
Quality | Exceeds FADGI ** guidelines, ISO 19264-1 |
Technical Specifications | |
Computer | 64 bit Linux, Intel i3, quad core processor, 8 Gigabyte RAM, 320GB HDD for extra large jobs |
Touchscreen | 7 inch color WVGA (wide VGA) touchscreen |
Monitor | 22 inch touchscreen |
USB Port | 2 USB Ports 3.0 |
Interface | 1 GBit Fast Ethernet with TCP/IP based Scan2Net® interface |
Camera | CCD camera |
Light Source | White LEDs, tested according to IEC 62471, no IR/UV emission Declaration about the Emission of UV and IR radiation |
Lamp Lifetime | 50,000 h (typ.) |
Dimensions | |
Dimensions Scanner (H x W x D) | 780 x 670 x 740 mm (30.7 x 26.4 x 29.1 inches) |
Weight Scanner | 52.5 kg (116 lbs.) |
Electrical Specifications | |
Electrical Connection | 100-240 V AC, 47 - 63 Hz (external power supply, complies with ECO standard CEC level VI) |
Power Consumption | < 0.5 W (Sleep) / 2.5 W (Standby) / 75 W (Ready to scan) / 130 W (Scanning) |
Ambient Conditions | |
Operating Temp | 5 to 40 °C (40 to 105 °F) |
Rel Humidity | 20 to 80 % (non-condensing) |
Noise | < 42 dB(A) (Scanning) / < 33 dB(A) (Standby) |
Technical changes, errors and omissions excepted. All information subject to change.